6
GAS CATEGORY: II2H3+
ELECTRIC POWER: 230 V - 50 Hz
If a hood is to be installed above the hob, refer to the hood
installation instructions to ensure the correct height above
the hob.
Hood and cabinetry clearances (mm)
Injectors table
Type of gas used
Type of
burner
Injector
label
Control
primary air
(X) (mm)
Nominal
heat flow
kW
Nominal
consumption
Reduced
heat flow
kW
Gas pressure (mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
wok
semi rapid
auxiliary
145
95
78
6
-
-
4,20
1,65
1,00
400 l/h
157 l/h
95 l/h
1,40
0,40
0,30
17 20 25
LIQUID
PETROLEUM GAS
(Butane) G30
wok
semi rapid
auxiliary
100
65
50
6
-
-
4,20
1,65
1,00
305 g/h
120 g/h
73 g/h
1,40
0,40
0,30
20 28-30 35
LIQUID
PETROLEUM GAS
(Propane) G31
wok
semi rapid
auxiliary
100
65
50
6
-
-
4,20
1,65
1,00
300 g/h
118 g/h
71 g/h
1,40
0,40
0,30
25 37 45
Type of gas used Configuration model Nominal heat flow kW
Overall nominal
consumption
Required air (m
3
)
for the combustion
1 m
3
of gas
G20 20 mbar 5 burners 9,50 904 l/h 9,52
G30 28-30 mbar 5 burners 9,50 691 g/h 30,94
G31 37 mbar 5 burners 9,50 678 g/h 23,80